Cellular flame structures and thermal characteristics of axi-symmetric ceiling fires: An experimental study and scaling analysis
文章来源:SKLFS  作者:SKLFS  发布时间:2022-06-09

Cellular flame structures and thermal characteristics of axi-symmetric ceiling fires: An experimental study and scaling analysis

Author: Fang, X., Hu, L. H., Qiu, A., Zhang, X. L., Kuwana, K.

Journal: Combustion and Flame

DOI10.1016/j.combustflame.2021.111442

KeywordsCeiling fire, Cellular flame, Flame length, Temperature profile, Heat flux, Flame cell size, diffusion flames, gas temperature, heat fluxes, pool fires, lengths

Abstract

The present study provides an experimental characterization of cellular flame structures and thermal characteristics of axi-symmetric ceiling fires. Experiments were carried out employing circular gaseous burners of various diameters at the ceiling facing downward using methane and propane as fuel. For this configuration, a hot buoyant diffusion flame burning beneath the cold fuel gas issuing from the ceiling above was naturally resulted in. A cellular flame structure, due to the inherent Rayleigh-Taylor instability of this buoyant flow configuration, was formed beneath the ceiling. The flame length (radius), temperature and heat flux distribution along the ceiling as well as characteristic inner cell size evolution of this special cellular flame were quantified experimentally for such ceiling fire of various conditions. Scaling analysis was performed to analyze the obtained parameters of the cellular flame structure and thermal characteristics of the ceiling fire. Results showed that the overall length (radius) of the cellular flame has a 2/5 power dependence on heat release rate and is independent of burner sizes and fuel types. Temperature profile and heat flux distribution for various conditions can be universally expressed as a function of L/Rf, the distance from the burner center normalized by the flame length. The characteristic cell size of the cellular flame was related to temperature, which can be well represented by a 2.33 power function based on the Rayleigh-Taylor instability scaling analysis. The cell size spatial evolution inside the cellular flame was self-similar corresponding to the dependence of temperature on relative position, and a non-dimensional function was obtained. This study provides fundamental data and a scaling analysis into the basic physics of the cellular flame behavior and thermal characteristics of ceiling fires. (C) 2021 The Combustion Institute. Published by Elsevier Inc. All rights reserved.


 
 
相关链接
Cellular flame structures and thermal characteristics of axi-symmetric ceiling fires: An experimental study and scaling analysis
联系我们
安徽省合肥市金寨路96号
中国科学技术大学
火灾安全全国重点实验室
邮政编码:230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
火灾科学国家重点实验室 版权所有 皖ICP备:002106505 号