首页  科学研究  学术论文  2021年
 
Effect of sample thickness on concurrent steady spread behavior of floor- and ceiling flames
文章来源:SKLFS  作者:SKLFS  发布时间:2022-06-09

Effect of sample thickness on concurrent steady spread behavior of floor- and ceiling flames

Author: Ma, Y. X., Hu, L. H., Huang, Y. J., Zhu, N., Fujita, O.

Journal: Combustion and Flame

DOI10.1016/j.combustflame.2021.111600

KeywordsFire, Concurrent flame spread, Sample thickness, Ceiling flame spread, Floor flame spread, Characteristic solid temperature, burning rate, heat-flux, pool fires, solid-fuel, pmma

Abstract

This paper presents an experimental investigation of the sample thickness effect on the concurrent flame steady spread behavior. Two configurations, ceiling flame and floor flame, as the fundamental diffusion combustion problems and representative scenarios of horizontal flame spread, are concerned herein. PMMA samples with thickness (delta) of 2, 3, 4, 5, 7, 9 mm were employed including both thermally-thin and thermally-thick conditions. A wind tunnel was used to provide the uniform concurrent airflow ranging from 0.3 m/s to 1.2 m/s in 0.3 m/s intervals. Flame characteristics and basic parameters to quantify the flame steady spread process have been studied, including flame spread rate (FSR), equivalent pyrolysis length as well as heat flux feedback in both pyrolysis and preheating zones. Results show that FSR decreases with sample thickness, being more sensitive to sample thickness for ceiling flame configuration than that for floor flame configuration. Equivalent pyrolysis length increases with sample thickness and ceiling flame's equivalent pyrolysis length is larger than floor flame's. Convection feedback is dominant under concurrent airflow regardless of the flame configuration, airflow velocity or sample thickness. In pyrolysis zone, the total heat flux to fuel surface of ceiling flame configuration is larger than that of floor flame configuration for thin samples due to buoyancy, but it decreases rapidly as sample thickness increases. In preheating zone, the heat flux decreases in power law for ceiling flame configuration while a piece-wise fitting is found for floor flame configuration, which is interpreted based on their inherent flame characteristic difference hence the thermal boundary layer conditions between these two configurations. To analyze the sample thickness effect on concurrent flame spread, a characteristic solid temperature (T*) is proposed by theoretical analysis, as an essential parameter to be used in the concurrent flame spread model to represent the coupling effect of heat input in gas phase and in-depth heat loss into the solid phase (or namely thermal inertia controlled by a characteristic thermal penetration depth). The calculated non-dimensional characteristic solid temperature (theta) shows to be less sensitive to flame configuration and concurrent airflow velocity for relatively thicker samples because the thermal penetration depth will tend to approach a limit. A general trend of its variation with sample thickness (delta) can be employed to predict the heat loss into solid phase and its predictive capability is verified by the experimental results. This work advances the fundamental understanding of the sample thickness effect on concurrent flame spread mechanism. (C) 2021 The Combustion Institute. Published by Elsevier Inc. All rights reserved.


 
 
相关链接
Effect of sample thickness on concurrent steady spread behavior of floor- and ceiling flames
联系我们
安徽省合肥市金寨路96号
中国科学技术大学
火灾安全全国重点实验室
邮政编码:230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
火灾科学国家重点实验室 版权所有 皖ICP备:002106505 号