首页  科学研究  学术论文  2023年
 
Study of elevated- and ground pool fire flame horizontal lengths in cross airflows: Air entrainment change due to Coand a effect
文章来源:SKLFS  作者:SKLFS  发布时间:2024-05-24

Study of elevated- and ground pool fire flame horizontal lengths in cross airflows: Air entrainment change due to Coand a effect

Author:Chen, Y. H., ukumoto, K., Zhang, X. L., Lin, Y. J., Tang, F., Hu, L. H.

Journal:Proceedings of the Combustion Institute

DOI:  10.1016/j.proci.2022.09.038

KeywordsElevated-and ground pool fire, Cross airflow, Flame horizontal lengths, Air entrainment, Coanda effect, large-eddy simulation, wind, attachment, behavior, geometry, Thermodynamics, Energy & Fuels, Engineering

Abstract

The present study investigates experimentally the flame horizontal lengths of elevated pool fires and compares with those of ground pool fires in cross airflows. This, as a fundamental problem considering air entrainment and combustion structure change due to Coand a effect resulted from ground at leeward side, has not been quantified but is of practical significance. Experiments were performed employing both elevatedand ground square propane pool fires of various heat release rates in cross airflows from 0 & SIM;3.0 m/s with 224 test conditions in all. The overall flame horizontal length could be physically divided into two parts: part, L b ). Both the L m and the overall flame horizontal length showed to be significantly larger for a ground pool fire than those of an elevated one, due to the ground constraint effect on air entrainment at leeward side (Coand a effect). L b /( u 2 /g ) or L m /( u 2 /g ) of elevated fires is proportional to that of ground fires. Large eddy simulations for two representative fire scenarios were further conducted utilizing an in-house version of FireFOAM. The purpose of the simulations was to uncover the underlying physics of combustion and flow structures observed in the experiment. Finally, a model was proposed based on analysis of air entrainment, momentum- and buoyancy effects, which described well the overall flame horizontal lengths of both elevatedand ground pool fires generally as a function of non-dimensional heat release rate, normalized volumetric air entrainment and Froude numbers using L m and L b as length scales. This work provides new observation and basic quantification on elevated- and ground pool fire flame horizontal lengths considering air entrainment & COPY; 2022 The Combustion Institute. Published by Elsevier Inc. All rights reserved.


 
 
相关链接
Study of elevated- and ground pool fire flame horizontal lengths in cross airflows: Air entrainment change due to Coand a effect
联系我们
安徽省合肥市金寨路96号
中国科学技术大学
火灾安全全国重点实验室
邮政编码:230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
火灾科学国家重点实验室 版权所有 皖ICP备:002106505 号