首页  科学研究  学术论文  2015年
 
M. H. Feng and J. Qin (2015) Journal Of Loss Prevention In the Process Industries 38 260-267.
文章来源:SKLFS    作者:SKLFS    发布时间:2016-03-01

M. H. Feng and J. Qin (2015) Extinguishment of hydrogen laminar diffusion flames by water vapor in a cup burner apparatus. Journal/Journal Of Loss Prevention In the Process Industries 38 260-267. [In English]
Web link: http://dx.doi.org/10.1016/j.jlp.2015.10.004
Keywords: Hydrogen safety; Diffusion flame; Water vapor; Nitrogen; Flame; suppression; OXYGEN-NITROGEN EXPLOSIONS; MIST; SUPPRESSION; EXTINCTION; MICROGRAVITY; MECHANISMS; MODEL; FIRE; AIR
Abstract: Transient computations with full hydrogen chemistry were performed to reveal the flame structure and extinguishment process of co-flow, hydrogen diffusion flame suppressed by water vapor. As the concentration of water vapor was increased, the flame detached away from the burner brim and formed an edge flame at the flame base. Water vapor showed larger chemical inhibition effect than nitrogen when extinguishing hydrogen flame, which was attributed to its enhanced third body effect in the reaction H + O-2+ M = HO2 + M. The minimum extinguishing concentration (MEC) of water vapor and nitrogen was predicted by Senecal formula and perfectly stirred reactor (PSR) model respectively. The MECs predicted by PSR model agree with the MECs calculated by Fluent, which shows that 1) the flame extinction is controlled by the flame base, and 2) radiation absorption is negligible. The measured MECs are in a reasonable agreement with the values calculated by Fluent, which demonstrates the accuracy of the CFD model. A simple model was used to investigate the relative importance of extinguishing mechanisms of water vapor. The results show that in a co-flow configuration the thermal cooling and chemical inhibition effect are the main extinguishing mechanisms in suppressing hydrogen diffusion cup burner flame. (C) 2015 Published by Elsevier Ltd.


 

 
 
相关链接
M. H. Feng and J. Qin (2015) Journal Of Loss Prevention In the Process Industries 38 260-267.
联系我们
安徽省合肥市金寨路96号
中国科学技术大学
火灾安全全国重点实验室
邮政编码:230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
火灾科学国家重点实验室 版权所有 皖ICP备:002106505 号