首页  科学研究  学术论文  2015年
 
H. Y. Yang, X. D. Zhou, L. Z. Yang and T. L. Zhang (2015) Materials 8 4210-4225.
文章来源:SKLFS    作者:SKLFS    发布时间:2016-02-25

H. Y. Yang, X. D. Zhou, L. Z. Yang and T. L. Zhang (2015) Experimental Studies on the Flammability and Fire Hazards of Photovoltaic Modules. Journal/Materials 8 4210-4225. [In English]
Web link: http://dx.doi.org/10.3390/ma8074210
Keywords: photovoltaic fires; flammability; fire hazards; cone calorimeter; CONE CALORIMETER; FLAME SPREAD; OXYGEN
Abstract: Many of the photovoltaic (PV) systems on buildings are of sufficiently high voltages, with potential to cause or promote fires. However, research about photovoltaic fires is insufficient. This paper focuses on the flammability and fire hazards of photovoltaic modules. Bench-scale experiments based on polycrystalline silicon PV modules have been conducted using a cone calorimeter. Several parameters including ignition time (t(ig)), mass loss, heat release rate (HRR), carbon monoxide (CO) and carbon dioxide (CO2) concentration, were investigated. The fire behaviours, fire hazards and toxicity of gases released by PV modules are assessed based on experimental results. The results show that PV modules under tests are inflammable with the critical heat flux of 26 kW/m(2). This work will lead to better understanding on photovoltaic fires and how to help authorities determine the appropriate fire safety provisions for controlling photovoltaic fires.


 

 
 
相关链接
H. Y. Yang, X. D. Zhou, L. Z. Yang and T. L. Zhang (2015) Materials 8 4210-4225.
联系我们
安徽省合肥市金寨路96号
中国科学技术大学
火灾安全全国重点实验室
邮政编码:230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
火灾科学国家重点实验室 版权所有 皖ICP备:002106505 号