Q. Y. Xie, R. Tu, X. Jiang, K. Li and X. J. Zhou (2014) The leakage behavior of supercritical CO2 flow in an experimental pipeline system. Journal/Applied Energy 130 574-580. [In English]
Web link: http://dx.doi.org/10.1016/j.apenergy.2014.01.088
Keywords: Leakage; Pipeline; Supercritical; Enhanced oil recovery; Carbon capture; and storage; CARBON CAPTURE; GEOLOGICAL STORAGE; TRANSPORTATION; MIXTURES; GAS; IMPURITIES; DIOXIDE; ENERGY

Abstract: The accidental release is one of the main risks during the pipeline transportation of supercritical CO2 for carbon capture and storage and enhanced oil recovery. The leakage of high pressure CO2 involves complex phenomena, including the expansion and flashing of the CO2 jet, dispersion of a dense CO2 cloud, falling of the solid CO2 and sublimation of the dry ice bank, as well as changes of pressure and temperature in the pipelines. A new experimental setup is developed to study the leakage behavior of high pressure CO2 flow in a circulation pipeline system, which is about 23 m long. The inner diameter of the pipeline is 30 mm. The pressure in the pipeline can be as high as 12 MPa with a maximum temperature of 50 degrees C through a high pressure pump and an electrically heated cloth around the pipeline. In addition, the velocity of the CO2 flow in the pipeline can be controlled in the range of 0-5 m/s by a circulation pump. The opening and closing of the small leakage hole can be remotely controlled by an operator. Pressure sensors are located nearby the leakage hole in the experimental pipeline system to monitor the pressure change during the CO2 leakage. Moreover, thirteen thermocouples are used to measure temperatures of the CO2 flow inside the pipe and on the surface of the pipeline. The experiments carried out show the typical characteristics of the supercritical CO2 flow leaked from a small hole. (C) 2014 Elsevier Ltd. All rights reserved.

 
 
相关链接
Q. Y. Xie, R. Tu, X. Jiang, K. Li and X. J. Zhou (2014) Applied Energy 130 574-580.
联系我们
安徽省合肥市金寨路96号
中国科学技术大学
火灾安全全国重点实验室
邮政编码:230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
火灾科学国家重点实验室 版权所有 皖ICP备:002106505 号