首页  科学研究  学术论文  2012年
 
Ji J, Fan CG, Zhong W, Shen XB, Sun JH (2012) International Journal Of Heat And Mass Transfer 55(17-18), 4817-4826.
文章来源:SKLFS    作者:SKLFS    发布时间:2013-09-21

Ji J, Fan CG, Zhong W, Shen XB, Sun JH (2012) Experimental investigation on influence of different transverse fire locations on maximum smoke temperature under the tunnel ceiling. International Journal Of Heat And Mass Transfer 55(17-18), 4817-4826. [In English]
Web link: http://dx.doi.org/10.1016/j.ijheatmasstransfer.2012.04.052
Keywords: Tunnel fire, Maximum smoke temperature, Transverse fire location, Longitudinal distribution, longitudinal ventilation, critical velocity, burning rate, pool fire, flow
Abstract: In former studies, fires were always assumed to occur at the longitudinal centerline of tunnels. In fact, fires will occur at any locations in tunnels, with different distances to the sidewall. A set of model scale experiments were carried out, to investigate the influence of different transverse fire locations on maximum smoke temperature under the tunnel ceiling. Results show that the restriction effect of the sidewalls of tunnels cause the maximum smoke temperature rise under the ceiling to increase compared with the unconfined space, even fires occurs at the longitudinal centerline. The maximum smoke temperature rises above the fire keep almost unchanged with the fire moving closer to the sidewall at the beginning and then increase significantly after the distance between the fire and the sidewall decreases to a certain value. For small pools of wall fire, the "mirror" effect is reasonable, and for large pools, will bring a relatively large error without considering the influence of the equivalent diameter of a wall fire, resulting in underestimating the mass flow rate of fire plume and then overestimating the smoke temperature. Under all fires, the maximum smoke temperature rise under the ceiling decreases exponentially as the longitudinal distance from fire increases. Correlations for related parameters are proposed. (C) 2012 Elsevier Ltd. All rights reserved.

 

 
 
相关链接
Ji J, Fan CG, Zhong W, Shen XB, Sun JH (2012) International Journal Of Heat And Mass Transfer 55(17-18), 4817-4826.
联系我们
安徽省合肥市金寨路96号
中国科学技术大学
火灾安全全国重点实验室
邮政编码:230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China
火灾科学国家重点实验室 版权所有 皖ICP备:002106505 号