Li LM, Mei P, Li S, Zhang HP (2012) Effect of longitudinal ventilation on heat release rate of tunnel fires. Tunnelling And Underground Space Technology 30, 230-232. [In English]
Web link: http://dx.doi.org/10.1016/j.tust.2012.02.020
Keywords: Tunnel fire, Heat release rate, Longitudinal ventilation, critical velocity, smoke flow, pool fire, systems
Abstract: The effect of the forced longitudinal ventilation on the heat release rate of tunnel fires is quantitatively analyzed and experimentally examined using the experimental data by Roh et al. (2007). Results indicate that the relative increment of tunnel fire heat release rates varies proportionally with the quantity uS/(g(1/2)r(5/2)) that represents the relative value of the longitudinal air volumetric flow rate to the mass loss rate of the fire source. (c) 2012 Elsevier Ltd. All rights reserved.
 
 