首页  科学研究  学术论文  2007年
 
He SQ, Hu Y, Song L, Tang Y (2007) Journal of Fire Sciences 25(2), 109-118.
文章来源:WOS    作者:SKLFS    发布时间:2011-08-16

He SQ, Hu Y, Song L, Tang Y (2007) Fire safety assessment of halogen-free flame retardant polypropylene based on cone calorimeter. Journal of Fire Sciences 25(2), 109-118. [In English]

Web link: http://dx.doi.org/10.1177/0734904107067109

Keywords:

flame retardant polypropylene; cone calorimeter; hazard; layered silicate nanocomposites

Abstract: This study addresses the fire performance of polypropylene compounded with different flame retardants in the cone calorimeter tests and UL-94 burning tests. The parameters measured include heat release rate, time to ignition, smoke, and CO/CO2 yields, on the basis of which fire hazard analysis is carried out. By injection-molding different burn-rated polypropylene composites into television back-enclosures and testing them in a full-scale cone calorimeter, we find that the one formulation of V-0 rating in the vertical burning test shows excellent flame retardance.

 
 
相关链接
He SQ, Hu Y, Song L, Tang Y (2007) Journal of Fire Sciences 25(2), 109-118.
联系我们
安徽省合肥市金寨路96号
中国科学技术大学
火灾安全全国重点实验室
邮政编码:230026
   
Tel:(+86)551 63601651
Fax:(+86)551 63601669
E-mail:sklfs@ustc.edu.cn
Copyright © 1990-2011 State Key Laboratory of Fire Science, University of Science and Technology of China